Quantcast
Channel: EngineerZone: Message List
Viewing all articles
Browse latest Browse all 22030

Re: EVAL-ADAU1701MINIZ: SigmaStudio's EQs control wrong frequencies

$
0
0

Hello Prius,

 

What is the sample rate set to within the SigmaStudio schematic?  This is important in order to generate the proper download parameters for the filters.  

 

What are your settings for the DSP Core Control Register's (address 0x881c) Sample Rate bits D0/D1 ?

 

Are you perhaps generating coefficients for 192 kHz operation within SigmaStudio, and the ADCs/DACs (or serial ports) are set for 48 kHz?   This could explain the frequency shift of the filters being 1/4th of the frequency of operation.   When I tell SigmaStudio for 192 kHz operation,  and set the program length to 1024 instructions/sample under the HW Configuration tab to set the core for 48 kHz operation, I can hear the frequency of the filters operate at 1/4th the intended frequency.  If I switch to 512 instructions/sample, the filter's center frequency is 1/2 what I expect.

 

The OLF bits in the "Serial Port Control Register 0"  (at address 0x081E) for L/R I2S clock operation must also match the instruction sample rate (although you probably are not connecting up to external ADCs or to the eval board so you can ignore this register).

 

ADAU1701_sample_rate.png

 

-JT


Viewing all articles
Browse latest Browse all 22030

Latest Images

Trending Articles



Latest Images