Re: AD215: is isolation voltage rating specified as continuous or transient?

$
0
0

Hi Wojtek,

 

We do not have any isolation certifications for the AD215.

If it helps though, footnote number 4 on page 3 of the datasheet provides some information on the isolation voltage:

 

"The isolation barrier (and rating) of every AD215 is 100% tested in production using a 5 second partial discharge test with a failure detection threshold of 150 pC. All “B” grade devices are tested with a minimum voltage of 1,800 V rms. All “A” grade devices are tested with a minimum voltage of 850 V rms."


Thanks,

Kris